DIGITAL TORQUE WRENCH
COATING THICKNESS GAUGE EC-770
EC-770

 

DESCRIPTION

 

This compact gauge can be used for non-destructive coating thickness measurement of non-magnetic coatings, e.g. paint, enamel, chrome on steel, and insulating coatings, e.g. paint and anodizing coatings on non-ferrous metals.

The internal probe can work on both principles, magnetic induction and the eddy currents. The probe can automatically detect the substrates type (Magnetic or not), and calculate the coating thickness and display it fast.

There are five data groups, and readings will be automatically stored to memory for general groups (Not for direct group). Each group has individual statistics, alarm limit settings and calibration. User can recall and delete specified readings easily. User does all operations via standard menu so easily. User can press the CAL button to start calibration freely.

 

FEATURES

 

  • 128 x128 dot matrix LCD display, standard menu operations;
  • Two measure mode: single and continuous;
  • Two group mode: direct (DIR) and general (GEN), readings will be lost when power off in direct mode, and not be lost in general mode. 80 readings can be stored for each group;
  • Zero point calibration and multi-point calibration (up to 4 points) for each group;
  • User can recall, delete specified readings, or delete group readings;
  • Statistics display: mean, minimum, maximum and standard deviation;
  • Three probe mode: auto, magnetic and eddy current; (only for SR2800FN )
  • User can set high or low limit alarm for each group;
  • Power off automatically;
  • USB interface to data transmission;
  •  Low battery and error indication;

 

Specifications:

 

Probe F Probe N
Measuring principle Magnetic induction Eddy Currents
Measuring range 0 to 1300um (0 to 51.2mils) 0 to 1300um (0 to 51.2mils)
Accuracy ± (3%+2um) ± (3%+2um)
±( 3%+0.078mils) ±( 3%+0.078mils)
0um~999um(1um) 0um~999um(1um)
1000um~1300um(0.01mm) 1000um~1300um(0.01mm)
Resolution
0mils~39.39mils(0.01mils) 0mils~39.39mils(0.01mils)
39.4mils~51.2mils(0.1mils) 39.4mils~51.2mils(0.1mils)
Calibration One point to four point calibration, zero point calibration, Basic
One direct group(readings not be stored to memory)
Four general group(readings will be stored automatically)
Data group NOTE: each group have individual statistics, alarm limit settings
and
calibration
Statistics No. of readings, mean, minimum, maximum and standard
deviation
Units um , mm, mils
Alarm User can set the high/low alarm limit
Alarm icon displayed on LCD when over the limit
Minimum curvature radius 1.5mm
convex
Minimum curvature radius 25mm
concave
Minimum measuring area Diameter 6mm
Minimum thickness of 0.5mm(0.02”) 0.3mm(0.012”)
substrate
Maximum measuring rate Two readings per second
Computer interface Download data via USB
Power supply Two 1.5V AAA battery(Not included)
Operation environment Temperature: 0 to 40C(32 to 104F); humidity: 20% to 90%rh
Storage environment Temperature: -20 to 70C(-4 to 158F)
Standard Compliance ROHS WEEE
Size 110mm×53mm×24mm(4.33″×2.09″×0.94″)
Case Material ABS; 92g(3.24 oz)

 

 

 

Package Include: The Coating Thickness gauge, Aluminium substrate, Standard foil, USB cable, Technical manual

 